Built for Business Continuity
Enterprise-grade infrastructure with the response guarantee that matters: when something goes wrong, our technical team—the same people who built the building—are on-site within 4 hours. Not days. Not weeks.
The 4-Hour Response Guarantee
Most buildings have a property manager who visits monthly—if you're lucky. LINK has a dedicated on-site team daily, including the technical staff who built the building and knows every system intimately.
When you report a technical issue, you're not entering a ticket queue. You're calling people who can walk to your floor. Our guarantee: 4-hour response for technical alarms, same day for standard issues.
What This Means in Practice
- ✓HVAC issue at 9am? Technician on-site by 11am, not next Tuesday.
- ✓Elevator fault? The person who installed it is still on call.
- ✓Power concern? Same-day diagnosis, not weeks of coordination.
- ✓After hours? 24/7 hotline staffed by people who can actually help.

Elevator Systems
| Category | Specification | Details |
|---|---|---|
| Passenger Elevators | 12 high-speed | Energy-recovery systems, intelligent dispatching |
| Goods Lift | 2 dedicated | Direct access to loading bay |
| Capacity | 1,000-2,000 kg | Varies by elevator bank |
| Speed | 2.5 m/s | Floor-to-floor in seconds |
| Dispatching | Intelligent grouping | Minimizes wait times at peak hours |
| Energy Recovery | Regenerative braking | Power returned to building grid |
5 Separate Entrances
No single point of congestion. Distribute arrivals across the building—essential for high-occupancy floors.
COVID-Proof Design
Multiple elevator banks and entrances allowed full operation during the pandemic. Ready for future disruptions.
Energy Recovery
Regenerative braking systems capture energy during descent and return it to the building grid.
Power & Backup Systems
| Category | Specification | Details |
|---|---|---|
| Primary Supply | Dual redundant feeds | From separate substations |
| Emergency Generator | available infrastructure | Common areas and essential services |
| UPS Capability | Tenant provisioned | IT room infrastructure ready |
| Internal charge of lighting | 9 W/m² | |
| Distribution | Raised floor | Flexible workstation positioning |
| Surge Protection | Building-wide | All distribution boards |
Data Center Readiness
For tenants requiring enhanced power and cooling, trading operations, data centers, specialized IT infrastructure, LINK offers dedicated zones that can be fitted out.
Internal charge of lighting
Efficient LED lighting throughout the building.
Data & Communications
| Category | Specification | Details |
|---|---|---|
| Building Backbone | Multi-carrier fiber | Swisscom, Colt, and additional carriers available |
| Horizontal Cabling | Category 6 UTP | All floors pre-wired |
| IT Rooms | 2 dedicated per floor | Cooled, secured, fire-protected |
| Riser Capacity | Expandable | Future-proofed for additional cables |
| Data Center Space | Available | Enhanced power and cooling zones |
| Mobile Coverage | Full building DAS | All major Swiss carriers |
IT Room per Floor
Each floor includes a dedicated IT room with:
- • Climate control (redundant cooling)
- • Fire suppression (clean agent)
- • Physical access control
- • Power distribution
- • Cable management systems
Multi-Carrier Access
Building backbone connected to multiple carriers for redundancy:
- • Swisscom
- • Colt
- • Additional carriers available
- • Competitive pricing through choice
Security & Access Control
| Category | Specification | Details |
|---|---|---|
| Reception | Staffed 07:00-19:00 | Trained security personnel |
| Access Control | Multi-level badge system | Building, floor, and suite levels |
| CCTV | 24/7 recording | Parking |
| After-Hours | Badge + code access | alarm response: 24/7 onsite presence |
| Alarm Response | 4-hour guarantee | On-site technical team |
| Fire Protection | Full sprinkler coverage | Smoke detection, alarms, evacuation |
Multi-Level Access
Tenants control their own space access. Building access, floor access, and suite access on separate tiers.
24/7 Recording
CCTV coverage of parking. Footage retained per Swiss privacy regulations.
Fire Safety
Full sprinkler coverage, addressable smoke detection, coordinated evacuation systems, and regular drills.
Logistics & Loading
| Category | Specification | Details |
|---|---|---|
| Loading Bay | Ground level access | Direct vehicle entry |
| Goods Lift | Dedicated freight elevator | Connects to all floors |
| Delivery Hours | Flexible scheduling | After-hours available |
| Parking | 423 spaces | Including delivery and VIP zones |
| Mail Handling | Central mailroom | Package acceptance and notification |
| Waste Collection | Managed service | Multi-stream recycling |
423 Parking Spaces
More parking than any new Geneva project can offer. New developments are restricted to 1 space per 200 sqm—LINK predates these limits.

See the Infrastructure Firsthand
Book a technical tour to see the elevator systems, IT rooms, and meet the team responsible for your building's operations.